- Total Error Band: typical ≤ 0.3% FS
- Compensated temperature: -40 to 255°F
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- Accuracies of ≤ ± 0.05 or 0.1% FS available
- 4 to 20 mA output
|
- Accuracy: ≤ ± 0.1% FS
- Operating temperature: -40 to 300°F
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- 4 to 20 mA output, loop powered
|
- Accuracy: ≤ ± 0.1 % FS
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- High overload: 3 X FS
- Operating temperature -40 to 185°F
- RS232C or RS485 interface
|
- Accuracy: ≤± 0.1 % FS
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- High overload: 3 x full scale
- Operating temperature: -40 to 185 °F
- Rugged construction, Fast delivery
|
- Accuracy: ≤ ± 0.1 % FS
- Full scale ranges from 360 to 10,000 psi
- Absolute or sealed gauge
- Compensated temperature: -40 to 212°F
- 316 Stainless Sensor - NACE Compatible
- Overall diameter less than one inch
|
- Accuracy: ≤ ± 0.1 % FS
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- High overload: 3 x full scale
- Operating temperature: -40 to 185°F
- Rugged construction, Fast delivery
|
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- High overload: 3 x full scale
- Operating temperature: -40 to 300°F
- Typical annual stability of 0.1%
|
- Accuracy: ≤ ± 0.1 % FS
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- 4-20 mA Output
- Operating temperature: -40 to 185º F
- 2 Switch outputs, 0-100% adjustable
|
- Total Accuracy: ≤ ± 0.15 % FS
- Compensated temperature: -40 to 185º F
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- Turn down ratio 4:1
- Adjustable response time
|
- Total Accuracy: ≤ ± 0.15 % FS
- Compensated temperature: -40 to 185º F
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- Turn down ratio 4:1
- RS485 (digital) and dual 4-20 mA signals
|
- Measuring range: -65 to 300º F
- Accuracy: ± 2º F typical, 32-160º F
- PT100 4-wire output option
- 316L SS or Titanium Construction
- Suitable for pressures up to 12,500 psi.
- 4-20 mA or 0-5/10 VDC Outputs
|
- Pressure Accuracy: ≤ ± 0.1 % FS
- Pressure ranges from 1 to 8,500 psi
- Temperature range: -40 to 300º F
- Temperature Accuracy: ± 4º F
- High overload: 3 x FS minimum
- 0-20/4-20 mA or 0-5/10 Vdc Output
|
- Total Error Band: typical ≤ 0.3% FS
- Compensated temperature: -40 to 212°F
- Full scale ranges from 1 to 15,000 psi
- Gauge, absolute or sealed gauge
- Accuracies of ≤ ± 0.1% FS
- 0 to 5 or 0 to 10 VDC output signal
|